{{indexmenu_n>08}} ====== Technical Specifications ====== ===== Dimensions ===== ^ Component ^ inches ^ millimeters ^ | Height (enclosure, overall) | 3.46 | 87.9 | | Width across mounting flange | 19.01 | 483 | | Width across body of enclosure | 17.44 | 443 | | Depth from front mounting flange to extremity of enclosure body | 22.71 | 576.8 | | Depth from Ops Panel to furthest extremity of enclosure | 24.79 | 629.6 | | Depth from front mounting flange to furthest extremity of enclosure | 23.74 | 602.9 | ===== Weights ===== ^ Component ^ Weight (kg) ^ Weight (lb.) ^ | Enclosure (empty) | 4.8 | 10.56 | | Drive Carrier | 0.9 | 1.98 | | Dummy Drive Carrier | 0.05 | 0.11 | | PCM | 2.7 | 5.94 | | I/O Module | 1.5 | 3.3 | | Blank I/O Module | 0.5 | 1.1 | | Enclosure (Fully Populated) \\ Total Weight (maximum) | 26 | 57.2 | ===== Environment ===== **Table A–1: Ambient Temperature and Humidity** ^ ^ Temperature Range ^ Relative Humidity ^ Max. Wet Bulb ^ | Operational | 5°C to 40°C | 8% to 80% non-condensing | 23°C | | Non-Operational | 1°C to +50°C | 8% to 80% non-condensing | 27°C | | Storage | 1°C to +60°C | 5% to 80% non-condensing | 29°C | | Shipping | -40°C to +60°C | 5% to 100% non-precipitating | 29°C | ^ Airflow | System must be operated with low pressure rear exhaust installation (Back pressure created by rack doors and obstacles not to exceed 5 pascals [0.5mm Water gauge]) | ^ Altitude, Operational | 0 to 3045 m (0 to 10,000ft) | ^ Altitude, Non-Operational | -305 to 12,192m (-1000 to 40,000ft) | ^ Shock, Operational | Vertical axis 5g peak 1/2 sine, 10ms | ^ Shock, Non-Operational | 20g 10ms 1/2 sine (test w drives) \\ 30g 10ms 1/2 sine (test w/o drives) | ^ Vibration, Operational | 0.21grms 5-500 Hz Random | ^ Vibration, Non-Operational | 0.8grms 2-200 Hz Random (test w drives) \\ 1.04grms 2-200 Hz Random (test w/o drives) | ^ Vibration, Relocation | 0.15g 2-200 Hz sine (test w drives) \\ 0.3g 2-200 Hz sine (test w/o drives) | ^ Acoustics | Sound Power \\ • SATA Drives: Less than 6.8 B Lwa - idle @ 20°C ambient \\ • SAS Drives: TBD | ^ Orientation & Mounting \\ • Rack Rails \\ • Rack Characteristics | 19" Rack mount (2EIA Units) \\ To fit 800mm depth racks compliant with the SSI Server Rack Specification \\ Back pressure not exceeding 5 pascals (0.5mm water gauge) | ===== Power Cooling Module (2 x 580W) ===== ^ Dimensions | 84.3mm High x 104.5mm wide x 340.8mm Long (3.32in x 4.11in x 37.03in) | ^ Maximum Output Power | 580 W | ^ Voltage Range | 100 - 240 VAC Rated | ^ Frequency | 50/60 Hz | ^ Voltage Range Selection | Auto Ranging: 90 - 264 VAC, 47/63Hz | ^ Maximum Inrush Current | 20A | ^ Power Factor Correction | ≥95% @ nominal input voltage | ^ Harmonics | Meets EN61000-3-2 | ^ Output | +5 V @: 42A, +12 V:@ 36A, +5 V standby voltage @ 2 A | ^ Operating Temperature | 0° to 57°C | ^ Hot Pluggable | | ^ Switches & LEDs | AC Mains Switch and four status indicator LEDs | ^ Enclosure Cooling | Dual axial cooling fans with variable fan speed control | ~~pgbreak~~ ===== Drive Carrier Module ===== **Important info:** Disk drives must be UL approved. Operating the LaCie 12big Rack Serial 2 with non-approved drives may invalidate the warranty. ==== Drive Carrier ==== ^ Module Dimensions | Height 26.6 mm Width 106.5 mm Depth 220.2 mm | ^ Weight | 0.8 kg (1.0" 300Gb drive) | ^ Operating Temperature | 5° C to 35° C | ^ Power Dissipation | 18 Watts maximum | === Drives === * 3.0Gb/s direct dock SAS (up to 15000 rpm) * 3.0Gb/s dual path SATA (up to 7200 rpm) via Active/Active SATA Transition Card ===== I/O Modules ===== Please refer to the SBB I/O Module Installation Guide (P/N xxxxx-01) for technical details of available I/O Modules.