{{indexmenu_n>09}} ====== Manage Disk Failure: Manual Rebuild ====== This section describes the procedure for manually rebuilding a degraded array when Auto-Rebuild is disabled and a dedicated spare drive is not available. You must have at least one unconfigured hard drive in the enclosure to perform the steps below. ~~pgbreak~~ ===== Rebuilding a degraded array ===== - Select the degraded array in the Storage pane. You will recognize the degraded array by its yellow icon. - Roll over the **Operation** tab and select **Rebuild**. \\ {{:products:raid-manager:screenshots:ss-lrm-manual-rebuild-01.jpg?700|}} \\ - LaCie RAID Manager displays hard drives that have not been added to an array. \\ {{:products:raid-manager:screenshots:ss-lrm-manual-rebuild-02.jpg?700|}} \\ - Select a hard drive from the list and choose **Submit**. \\ {{:products:raid-manager:screenshots:ss-lrm-manual-rebuild-03.jpg?700|}} \\ - Choose the Property tab for the array. The Background Activity State shows that the rebuild is running. \\ {{:products:raid-manager:screenshots:ss-lrm-manual-rebuild-04.jpg?700|}} \\