User Tools

Site Tools


Repairing RAID Configurations

In the event that an individual hard disk fails in the 4big Rack Office, contact your LaCie reseller or LaCie Customer Support for technical assistance. If the server is within the warranty period, please use the replacement hard drive provided by LaCie.

In the example below, Disk 1 is Missing and both the Mirrored and RAID 5 arrays have Failed Redundancy.

Once the disk has been replaced, please make certain to repair the RAID arrays in the following order:

  1. Mirror (Data2 in this example but the same order is in effect if one of the Disk 3 in the System Mirror fails.)
  2. RAID 5

Important info on Disk 2 failure: If Disk 0, Disk 1, or Disk 3 must be replaced, please continue with the instructions in Repair the Mirror Array. If Disk 2 has failed, please see Disk 2 Failure and Boot Order.

Repair the Mirror Array

The steps below will illustrate how to repair Mirrored and RAID 5 arrays following disk failure. The two partitions from the failed hard drive, Disk 1 in this example, are used for both Mirrored and RAID 5 arrays.

Note: Please wait until you have received and installed the replacement disk before attempting to repair the RAID.

  1. Remove the failed Disk 1 and insert the replacement. See the Hardware Maintenance section of the 4big Rack Office User Manual for instructions on adding new drives. Please make certain that you replace the correct drive.
  2. Power on the server. It may take 5 to 10 minutes for the server to be ready.
  3. Launch the Dashboard from a Windows workstation on the same network as your LaCie 4big Rack Office. Start > All Programs > Windows Home Server 2011 > Windows Home Server 2011 Dashboard
  4. Select the Home tab.
  5. Click once on COMMON TASKS.
  6. Click once on Disk Management.
  7. Upon launch Disk Management will prompt you to initialize the drive. LaCie recommends initializing the disk as MBR to match the default configuration. Click “OK” to continue.
  8. The replacement disk is listed as Unallocated.
  9. The mirror must be broken before rebuilding it with the replacement disk. Right-click on the Data2 volume to select Remove Mirror… Please note that the same procedure should be followed if one of the disks in the System mirror has failed.
    Remove Mirror - Data2
  10. In the Remove Mirror pop-up window, select Missing. Click Remove Mirror.
  11. Click Yes at the Disk Management prompt.
  12. The mirror has been successfully removed.
  13. Right click on the Data2 partition to select Add Mirror…
  14. From the Add Mirror pop-up window, select your replacement disk (in this example, Disk 1). Click Add Mirror.
  15. Click Yes at the Disk Management pop-up window. The Mirror will begin the resynching operation.
  16. Go to Repair the RAID 5 Array to continue. You may repair the RAID 5 array while the Mirror is resynching.

Repair the RAID 5 array

Please follow the instructions in Repair the Mirror Array before attempting the steps below.

  1. Right click on any volume in the RAID 5 array except for the Missing disk. Select Repair volume.
  2. In the Repair RAID-5 Volume window, choose the disk to repair the Data1 volume (in our example, Disk 1). Click OK. In most instances, the Data1 volume will start resynching (See Plex Error When Resynching RAID 5 if you receive a plex error.) Please be patient since the repair might take more than 40 hours depending upon the type of drive used. While there may be a slight reduction in performance, you may use the RAID 5 array while it is resynching.