The system must not be run without all units in place. In order to comply with applicable safety, emission and thermal requirements, no covers should be removed and all bays must be populated.
Permanently unplug the unit if you think that it has become damaged in any way.
Shut down and unplug the unit before moving it.
The 4big Rack Office unit must only be operated from a power supply input voltage range of 100 to 240 VAC, 50 to 60 Hz.
Make sure that the socket outlets are located near the equipment and are easily accessible.
Before removal/replacement of the power supply, disconnect supply power for complete isolation.
A safe electrical ground connection must be provided to the power cord. Check the grounding of the enclosure before applying power.
Provide a suitable power source with electrical overload protection to meet the requirements laid down in the technical specification.
Never expose your device to rain, or use it near water, or in damp or wet conditions. Never place objects containing liquids on the enclosure, as they may spill into its openings. Doing so increases the risk of electrical shock, short-circuiting, fire, or personal injury.
Always unplug the device from the electrical outlet if there is a risk of lightning or if it will be unused for an extended period of time. Otherwise, there is an increased risk of electrical shock, short-circuiting, or fire.
Hot surfaces (heatsinks) are exposed when the enclosure top cover is removed. Disconnect power and allow the enclosure to cool before working inside the system.
Rotating fan blades are exposed when the enclosure top cover is removed.
When pulled out from the rack, the enclosure must not be used as a shelf to support any other object.
The rack cabinet must be capable of supporting the total weight of the installed enclosure(s) and the design should incorporate stabilizing features suitable to prevent the cabinet from tipping or being pushed over during installation or in normal use.
When loading a rack cabinet with the units, fill from the bottom up and empty it from the top down.
The cabinet design should take into consideration the maximum operating ambient temperature for the unit, which is 35°C.
The cabinet should have a safe electrical distribution system. It must provide overcurrent protection for the unit and must not be overloaded by the total number of units installed in the rack. When addressing these concerns, consider the electrical power consumption rating shown on the product.
The electrical distribution system must provide a reliable ground for each unit and for the cabinet.
The power Supply Unit has a ground leakage current of 3.5mA. The design of the electrical distribution system must take into consideration the total ground leakage current from all the power supplies in all the units.
When configured, the cabinet must meet the safety requirements of IEC 60950-1 2nd edition.
The 4big Rack Office enclosure is designed for installation into an industry standard 19 inch rack cabinet subject to the following requirements:
The top cover on the enclosure provides access to the RAM, hard drives, and riser card slot in the motherboard.
Upon replacement, the cover MUST be secured by screwing tight the appropriate screws at the rear with a screwdriver (this is to prevent users/operators from accessing service areas).
Observe all conventional ESD precautions when handling 4big Rack Office internal components. Avoid contact with backplane components, module components, etc.
Drives are fragile and must be handled with care during removal/replacement.